- Description
The VE.Bus BMS V2 is a Battery Management System (BMS) designed to
interface with and protect a single, or multiple Victron Lithium Battery
12,8V & 25,6V Smart (LiFePO4 or LFP) in systems that have Victron
inverters or inverter/chargers with VE.Bus communication. It monitors
and protects the batteries against the over voltage and under voltage of any
individual cell, and also over temperature or under temperature
conditions.
Based on the status of the battery or batteries, the BMS will:
Generate a pre-alarm signal to alert of an imminent cell under voltage conditions.
Disable
inverting in VE.Bus inverters or inverters/chargers via VE.Bus, and
disable other loads via the ‘Load Disconnect’ terminal in the event of a
cell under voltage conditions.
Disable charging in VE.Bus
inverters or inverters/chargers via VE.Bus and disable other chargers via
the ‘Charge Disconnect’ terminal in the event of a cell overvoltage, under-temperature, or over-temperature conditions.
The VE.Bus BMS V2 has additional features such as:
Remote on/off terminals.
Ability to disable VE.Direct and VE.Can solar chargers via a GX device.
Allowing
control of the VE.Bus inverter/charger from multiple devices, like the
Digital Multi Control, the VE.Bus Smart dongle and/or a GX device.
Auxiliary power input and output terminals that allow a GX device to remain powered in the event of a system shutdown.